Lakeland, Florida 33805

  • Intermittent Catheterization

Purpose:

The Catheter Science C3 "Umbrella Catheter" has been developed for management of urinary retention in patients who are either using a Foley or Self Intermittent Catheter. This device is inserted into the bladder in an extended state and once the stylet is removed the device folds into collapsed state. A thread is attached to the device and traverses thru the urethra and is attached to a bobber. With gentle traction on the thread the device engages the bladder neck and the central tube extends which allows for the flow of urine. Once voiding is complete, the thread is released and the device collapses back to the folded state into the bladder. Each voiding cycle is accomplished in a similar fashion. This is a novel technique in which the bladder is catheterized with the device from within the bladder into the bladder neck and urethra. The standard self catheter technique is for placement of a catheter from the outside into the urethra and into the bladder.


Study summary:

Interventional (clinical trial): Participants are assigned prospectively to an intervention or interventions according to a protocol to evaluate the effect of the intervention(s) on biomedical or other health related outcomes. This single arm, prospective study is designed to produce valid scientific evidence regarding: 1. Safety and efficacy of the Catheter Science C3 "Umbrella Catheter" in establishing urinary drainage and allowing the control of micturition when indwelling for up to 7 days. 2. The reduction in Catheter Acquired Urinary Tract Infection (CAUTI) A single arm study design was chosen because there is no alternative treatment to serve as an appropriate control. The C3 catheterizes the bladder with engagement into the bladder neck under the control of the patient or care giver. A Foley catheter, a pre- amendment device, was considered for a control treatment. However, although a Foley catheter is used to establish urinary drainage with close to 100% efficacy, it does not restore voiding function like the C3, and severely impairs activities of daily life. The intrinsic design flaws of a Foley catheter traversing thru the urinary passage which violates the anatomical protective points which help to avoid bacterial contamination. The distal 1/3 portion of the urethra in females is commonly colonized with bacteria. Standard Catheter technique traverses from the outside into the entire length of the urethra to drain the bladder. The standard self catheter flow characteristics are impacted due to the placements of the "eyes" to the catheter lumen. The C3 lumen is open in line with the flow.


Criteria:

Inclusion Criteria: 1. Patients with Bladder Dysfunction requiring mechanical drainage. 2. Patients with actual urinary retention Exclusion Criteria: 1. Inability to undergo bladder catheterization (e.g., urethral stricture or history of urethral stricture) 2. Gross hematuria


NCT ID:

NCT03353571


Primary Contact:

GAINES W HAMMOND, MD
Phone: 863-680-7300
Email: GHAMMOND@WATSONCLINIC.COM


Backup Contact:

Email: EHALL@WATSONCLINIC.COM
ELAYNE HALL
Phone: 863-680-7300


Location Contact:

Lakeland, Florida 33805
United States

GAINES W HAMMOND, MD
Phone: 863-680-7300
Email: GHAMMOND@WATSONCLINIC.COM

Site Status: Recruiting


Data Source: ClinicalTrials.gov

Date Processed: September 27, 2021

Modifications to this listing: Only selected fields are shown, please use the link below to view all information about this clinical trial.